부품 정보
90.0 degrees elbow for outlet, mtg plates
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
37.500 inches
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Flange
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Flange 1st outlet
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Flange single inlet
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
22.000 inches
MRC:
The length of a straight line which passes through the center of the outlet,and terminates at the inside circumference.AJLW
Outlet Inside Diameter:
Any acceptable
MRC:
Indicates the design type of the item.APGF
Design Type:
Wet
MRC:
Indicates the type of coolant used with the item.ARNA
Coolant Type:
Water
MRC:
The basic design of the muffler.ARND
Muffler Design:
Multipass
MRC:
The physical configuration of the body.ARNG
Body Shape:
Round
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
Any acceptable
MRC:
The location of the inlet.ARNJ
Inlet Location:
On side 2.000 in. From vertical @centerline of body, on side directly opposite other inlet
MRC:
A measurement of the longest dimension of the inlet projection,in distinction from width.ARNK
Inlet Projection Length:
4.000 inches
MRC:
A measurement of the longest dimension of the inlet projection,in distinction from width.ARNK
Inlet Projection Length:
4.000 inches 1st outlet
MRC:
A measurement of the longest dimension of the inlet projection,in distinction from width.ARNK
Inlet Projection Length:
4.000 inches single inlet
MRC:
The physical configuration of the inlet flange.ARNL
Inlet Flange Shape:
Round
MRC:
The physical configuration of the inlet flange.ARNL
Inlet Flange Shape:
Round 1st outlet
MRC:
The physical configuration of the inlet flange.ARNL
Inlet Flange Shape:
Round single inlet
MRC:
The type and number of inlet flange mounting provisions provided.ARNM
Inlet Flange Mounting Provision And Quantity:
6 holes
MRC:
The type and number of inlet flange mounting provisions provided.ARNM
Inlet Flange Mounting Provision And Quantity:
6 holes 1st outlet
MRC:
The type and number of inlet flange mounting provisions provided.ARNM
Inlet Flange Mounting Provision And Quantity:
6 holes single inlet
MRC:
The length of a straight line passing through the center of an inlet flange mounting hole,and terminating at the circumference.ARNN
Inlet Flange Mounting Hole Diameter:
0.688 inches
MRC:
The length of a straight line passing through the center of an inlet flange mounting hole,and terminating at the circumference.ARNN
Inlet Flange Mounting Hole Diameter:
0.688 inches 1st outlet
MRC:
The length of a straight line passing through the center of an inlet flange mounting hole,and terminating at the circumference.ARNN
Inlet Flange Mounting Hole Diameter:
0.688 inches single inlet
MRC:
The spacing of the inlet flange mounting provision.ARNT
Inlet Flange Mounting Provision Spacing:
12.000 in. Bolt cirle diameter 1st inlet, 12.000 in. Bolt circle diameter 2nd inlet
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Unthreaded
MRC:
The location of the outlet.ARTJ
Outlet Location:
Centrally located in end section of body
MRC:
A measurement of the longest dimension of the outlet projection,in distinction from width.ARTK
Outlet Projection Length:
Any acceptable
MRC:
The length of a straight line which passes through the center of the outlet,with terminated points on the outside circumference.ARWA
Outlet Outside Diameter:
8.625 inches
MRC:
A narrative description of the type of water inlet connection.ARWE
Err Default:
Err default
MRC:
A narrative description of the type of water inlet connection.ARWE
Water Inlet Connection Type:
Unthreaded
MRC:
The location of the water inlet.ARWF
Err Default:
Err default
MRC:
The location of the water inlet.ARWF
Water Inlet Location:
In @end section of body, opposite outlet
MRC:
A measurement of the longest dimension of the water inlet projection,in distinction from width.ARWG
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of the water inlet,and terminates at the outside circumference.ARXC
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of the water inlet,and terminates at the outside circumference.ARXC
Water Inlet Outside Diameter:
1.000 inches
MRC:
The length of a straight line which passes through the center of the water inlet,with terminated points on the inside circumference.ARXD
Err Default:
Err default
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Steel
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Any acceptable