부품 정보
Indicator, sight, liquid
TXT
묘사:
Flow Rate Indicating Meter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
10.75 inches
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Threaded
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Desal plnt re
MRC:
An indication of whether or not an integral safety device is included.AHZU
Integral Relief Valve:
Not included
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Various registors and transmitters ordered separately
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Float magnetically coupled to indicator in extension chamber
MRC:
Indicates the design type of the item.APGF
Design Type:
Case
MRC:
Indicates the type of unit.APQB
Unit Type:
Mounted
MRC:
The number of scales on the item.APSJ
Scale Quantity:
0
MRC:
The structural characteristic of the item.ARQS
Construction:
Any acceptable
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Threaded
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Bronze
MRC:
The means of attaching the item.AXGY
Mounting Method:
Direct line
MRC:
Designates the size of the outlet connection included on the item.BHCM
Outlet Connection Size:
1 inch
MRC:
An indication of whether or not a base(s) is included.BHJT
Base:
Not included
MRC:
An indication of whether or not an integral heat source is included.BNHN
Integral Heat Source:
Not included
MRC:
The maximum working pressure at which an item is designed to operate.BPHD
Maximum Working Pressure:
150.0 pounds per square inch
MRC:
Designates the size of the inlet connection included on the item.CPZD
Inlet Connection Size:
1 inch
MRC:
The number of metering tubes provided.CPZF
Metering Tube Quantity:
1
MRC:
The maximum amount of water for which the item is rated,expressed in gallons per minute.CPZG
Maximum Water Capacity In Gallons Per Minute:
70.0
MRC:
An indication of whether or not a spinning float is included.CPZM
Spinning Float:
Not included
MRC:
An indication of whether or not an integral pulsation dampener is included.CPZN
Integral Pulsation Dampener:
Included
MRC:
The inlet connection position for which the item is designed.CPZP
Inlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of inlet connection device provided.CPZQ
Inlet Connection Device Type:
Stationary
MRC:
The outlet connection position for which the item is designed.CPZR
Outlet Connection Position For Which Designed:
Horizontal
MRC:
An indication of whether or not an alarm signal is included.CPZT
Alarm Signal:
Not included
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Magnetic pick up and scale sepatate accessory
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Itb-072-09
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Uses positive displacement wobble plate to sense flow
MRC:
The alpha-numeric-alpha designation used to identify the type and/or model of the basic item.TMDN
Type/model Designation:
Industrial rcdl