MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 10.172 inches and 10.297 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
Between 0.406 inches and 0.469 inches
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
250.0 megahertz blank
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms blank
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms blank
MRC:
The identifying numeric code of the originator that controls or manufactures the input terminal.AHBN
Input Terminal Manufacturer Code:
80058
MRC:
The specification,standard,or manufacturers identification number or symbol used to identify the input terminal.AHBP
Input Terminal Identification:
Ug-89c/u
MRC:
The identifying numeric code of the originator that controls or manufactures the output terminal.AHBS
Output Terminal Manufacturer Code:
80058
MRC:
The specification,standard,or manufacturers identification number or symbol used to identify the output terminal.AHBT
Output Terminal Identification:
Ug-89c/u
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 terminal
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
0.3 blank
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 connector, plug input 1st function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 connector, plug output 2nd function
MRC:
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
Specified Frequencies Of Discrimination Per Function:
1.00 megahertz blank and 500.00 megahertz blank and 850.00 megahertz blank and 2.50 gigahertz blank
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Metal
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
1.00 megahertz blank and 500.00 megahertz blank
MRC:
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 blank and 3.0 blank and 60.0 blank and 60.0 blank
MRC:
The metallic,nonmetallic,and/or chemical properties with which the body is plated,dipped and/or coated. the treatment is designed to protect the body surface/s/ and cannot be wiped off.CRST
Body Surface Treatment:
Silver
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Externalsurface silver
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Silver
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Round terminal/terminals on opposite surfaces