TXT
				
				
					묘사:
				
				
					Circuit Breaker Tripper				
			 
			
										
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Circuit breaker p/n hld3500v onboard 420 ft wagb coast guard vessels					
				 
							
					
						MRC:
						The number of poles included in the item.AKPX
					 
					
						Pole Quantity:
					
					
						3					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Adjustable trip release					
				 
							
					
						MRC:
						The maximum current load that each pole is rated to carry continuously.CPLM
					 
					
						Maximum Continuous Load Current Rating Per Pole:
					
					
						500.0 amperes ac all locations and 500.0 amperes dc all locations					
				 
							
					
						MRC:
						Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
					 
					
						Operating Voltage Type And Rating Per Pole In Volts:
					
					
						600.0 ac all locations and 250.0 dc all locations					
				 
							
					
						MRC:
						Indicates the type of electrical condition that will cause the device to trip.CPRH
					 
					
						Circuit Protection Type:
					
					
						Overcurrent all locations					
				 
							
					
						MRC:
						The means by which the trip mechanism is released.CPRJ
					 
					
						Trip Release Method:
					
					
						Thermal-magnetic all locations					
				 
							
					
						MRC:
						Denotes the type of trip release action.CPRL
					 
					
						Trip Release Characteristic:
					
					
						Instantaneous all locations					
				 
							
					
						MRC:
						The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.CPRN
					 
					
						Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
					
					
						125.0 all locations					
				 
							
					
						MRC:
						Indicates the type and number of actuators provided for manual control.CPRT
					 
					
						Manual Actuator Type And Quantity:
					
					
						1 toggle					
				 
							
					
						MRC:
						Denotes the action imparted by actuator operation.CPRW
					 
					
						Actuator Function:
					
					
						Trip-reset					
				 
							
					
						MRC:
						An indication of the designated position of the actuator.CPRX
					 
					
						Actuator Position Designation:
					
					
						At pole two					
				 
							
					
						MRC:
						The minimum and maximum values of current to which an adjustable trip setting device may be set per pole,expressed in amperes.CPSF
					 
					
						Adjustable Trip Setting Current Range Per Pole In Amps:
					
					
						+1000.0/+2000.0 ac all locations					
				 
							
					
						MRC:
						The temperature of the medium surrounding the trip release at which it can be operated continuously.CRCF
					 
					
						Trip Release Ambient Tempurature Rating:
					
					
						50.0 degrees celsius  all locations					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						60.0 all locations					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						6 compression