부품 정보
						Energy efficient cv or cv/cc switcher
					 
				 
						
			
				
					TXT
				
				
					묘사:
				
				
					Linear Microcircuit				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Iiilength:
					
					
						9.32 millimeters 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Iiiwidth:
					
					
						3.00 millimeters 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						6.10 millimeters 					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-40.0 to 150.0 degrees celsius					
				 
							
					
						MRC:
						The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
					 
					
						Storage Tempurature Range:
					
					
						-65.0 to 150.0 degrees celsius					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the inclosure is fabricated.CQSJ
					 
					
						Inclosure Material:
					
					
						Plastic					
				 
							
					
						MRC:
						Indicates the physical configuration of the inclosure.CQSZ
					 
					
						Inclosure Configuration:
					
					
						Dual-in-line					
				 
							
					
						MRC:
						The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated. the treatment is designed to protect the terminal surface(s) and cannot be wiped off.CWSG
					 
					
						Terminal Surface Treatment:
					
					
						Tin and solder					
				 
							
					
						MRC:
						Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
					 
					
						Special Features:
					
					
						Typical drain supply voltage 50v;  combined primary clamp,  feedback,  ic supply and loop compensation;  auto-start;  thermal and current limit protection;  ecosmart,  meets california energy commission,  energy star and eu requirements;  constant current/constant voltage switcher					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						8 flat leads