TXT
묘사:
Radio Frequency Cable
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A measure of the opposition to the flow of electrical current.AAPP
Electrical Resistance:
5.36 ohms per 1000 feet
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
0.044 inches single conductor
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
0.195 inches all conductors
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
00019&72&c&0
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
1
MRC:
The property of a system of conductors and dielectrics which permits the storage of electricity when potential difference exists between the conductors,expressed in picofarads.AXGH
Capacitance In Picofarads:
24.5 per foot
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Solid single conductor
MRC:
The geometric configuration of the conductor when viewed in cross-section.CXDM
Conductor Cross-sectional Shape:
Tubular solid 1st conductor
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
1000.0 dc rated working voltage single conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black core wrap
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core wrap