TXT
묘사:
Fire Control System Test Set
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
13.000 inches and 8.500 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
17.000 inches and 17.250 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.000 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
-200.0 volts and 200.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.000 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Cable; cable; cable; cable; cable; cable; rack assembly
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 and 1 and 1 and 1 and 3 and 1 and 1
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Buord; buord; buord; buord; buord; buord; buord
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
1401271 drawing no. And 1401272 drawing no. And 1401273 drawing no. And 1401274 drawing no. And 1401275 drawing no. And 1401276 drawing no. And 1468570 drawing no.
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Aluminum carrying case and aluminum carrying case
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Multiple item w/carrying case
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Measurement of voltage and resistance; observe voltage wave forms; test components
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Meter unit assembly, range minus 40 to 0 to plus 40 v dc, range 0.0005 to 0.005 rms v ac, 0.005 to 0.05 rms v ac, o.05 to 0.5 rms v ac, 0.5 to 5 rms v ac, 5 to 50 rms v ac, 50 to 500 rms v ac, range 0 to minus 1.2/12/60/300/1200 v dc, 0 to plus 1.2/12/60/300/1200 v dc, 0 to 1.2/12/60/300/1200 v ac, resistance range 0 to 1000 ohms/100000 ohms/1 meg/10 meg/1000 meg dc; oscilloscope unit, deflection sensitivity through amplifier 0.075 rms v per in., vertical and horizontal frequency response 1 to 50000 cps on x axis 5 cps to 2 mc on y axis, saw-tooth sweep range 3 to 50000, cps sine wave sweep 60 cps, phase shift indicator range 0 to 360 deg
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
6.750 inches and 10.000 inches