부품 정보
Dial plate to e etched on black anodized aluminum; attenuator to be painted grey enamel; entire assembly except dial plate to be sprayed with clear lacquer
TXT
묘사:
Variable Attenuator
MRC:
The primary application for which the item is designed.AAFS
Application Design:
Transmission line
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Aluminum
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Coaxial type
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 6.490 inches and 6.550 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
5.860 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
4.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 5.347 inches and 5.405 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.950 inches
MRC:
Equal or unequal distances between graduations representing values of measurement on a scale.ABWF
Scale Linearity:
Nonlinear
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.196 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-30.0/+71.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Radar set, an/fps-20
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.60
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
Bnc
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
600.0 milliwatts average
MRC:
The overall limits of decrease of the amplitude ratio of a signal between the input and output of the item,expressed in decibels.ASYD
Overall Attenuation Range In Decibels:
+6.0/+23.0
MRC:
The means by which the attenuation can be varied from the minimum to the maximum setting.ASYF
Attenuation Variation Method:
Stepped
MRC:
The number of intervals at which the item can be set.ASYG
Step Position Quantity:
18
MRC:
The amount of attenuation between adjacent steps,expressed in decibels.ASYH
Attenuation Per Step In Decibels:
1.0
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
Frequency Range:
Between 1.250 megahertz and 1.350 megahertz
MRC:
The overall limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.BQNR
Overall Attenuation Accuracy In Decibels:
-1.00/+1.00
MRC:
Indicates the type and number of facilities for adjusting the item.CQTQ
Adjustment Device Type And Quantity:
1 knob and 1 shaft
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Four position rectangular
MRC:
The total opposition (resistive and reactive) to the flow of alternating current,expressed in ohms.CTGG
Impedance Rating In Ohms:
50.0 input-output
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 connector, coaxial, female
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Antennas, waveguides, and related equipment