TXT
묘사:
Rotary Vacuum Pump Unit
MRC:
The power required to start and operate the item at the actual rated capacity,including all accessories.AAXW
Brake Horsepower Required:
30.000
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Flanged
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded internal
MRC:
Indicates the type of connection between the prime mover and the shaft.AAYX
Drive Connection Type:
Multistrand v-belt
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a body surface.ABEM
Body Surface Treatment:
Any acceptable
MRC:
Items furnished as accessories which are not specified elsewhere.ABFF
Furnished Items:
Belt guard
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
35.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
61.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
29.125 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The cooling medium used to maintain the required operating temperature of the item.ACZV
Cooling Medium:
Water
MRC:
The ultimate maximum vacuum,expressed in terms of absolute pressure,that may be produced by or applied to an item.ADLE
Vacuum Rating:
0.01 torr
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The element,compound,or mixture of which the pump body is fabricated,excluding any surface treatment.AENE
Pump Body Material:
Any acceptable
MRC:
The specific gas with which the item is designed to be used.AENF
Specific Gas For Which Designed:
Air
MRC:
Indicates the type of pumping element included on the item.AENG
Pumping Element Type:
Rotary piston
MRC:
The style designation indicating the configuration that most nearly corresponds to the shape of the intake connection flange.AENQ
Intake Connection Flange Shape Style:
Round
MRC:
The length of a straight line which passes through the center of the intake connection flange,and terminates at the outside circumference.AENV
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of the intake connection flange,and terminates at the outside circumference.AENV
Intake Connection Flange Outside Diameter:
11.000 inches
Intake Connection Flange Thickness:
1.188 inches
Intake Connection Bolt Hole Quantity:
8
Intake Connection Bolt Hole Diameter:
0.875 inches
Intake Connection Bolt Circle Diameter:
9.500 inches
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
845.0
MRC:
The device which prevents or reduces the amount of condensable vapors from entering and contaminating the item.AEQG
Vapor Condensation Preventative Device:
Gas ballast valving
MRC:
The volume of air passed per unit of time through an item.AEQH
Air Displacement Rate:
530.0 cubic feet per minute in free air
MRC:
An indication of the system for which the item is designed.AERP
System Design:
Noncorrosive
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
74.7 and 37.4
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the discharge connection.ASAZ
Discharge Connection Thread Size And Series/type Designator:
3.000-8 npt
MRC:
Indicates the type of control device provided.BDML
Control Device Type:
Motor starter
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Separator tank
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
230.0 and 460.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
The military service that initially procured the item from the contractor.KZTS
Cognizant Service:
Usaf