MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
1.875 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
6.429 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
1.875 inches
MRC:
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AASA
Thread Length:
0.5310 inches single end
MRC:
The number of splines on or in the item.ABSA
Spline Quantity:
18 single end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.312 inches first end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.390 inches second end
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc input
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise single end
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Totally enclosed
MRC:
Indicates the specific arrangement in which wire is wound on a form or is formed by winding.AXCP
Winding Type:
Permanent magnet
MRC:
A measurement of the longest dimension of a spline,in distinction from width.AXFH
Spline Length:
0.7400 inches single end
MRC:
The means of attaching the item.AXGY
Mounting Method:
Pad
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The drive shaft position as related to the armature axis.BFLY
Geared Head Output Shaft Alignment Position:
Inline w/armature single end
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Nonventilated
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
Load
MRC:
Indicates the torque rating,and its type.BKPH
Torque Rating And Type:
21.0 inch-ounces stalled
MRC:
The means by which the speed is controlled and the type of device used.BKPP
Speed Control Method And Device Type:
Automatic mechanical
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Commercial
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Horizontal mounting position and vertical mounting position
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
1.271 inches single end
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.625 inches
MRC:
The nominal center to center distance between the mounting facilities parallel to the height.CWGD
Center To Center Distance Between Mounting Facilities Parallel To Height:
1.625 inches
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
1.400 single output
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
27.0 line to neutral single input
MRC:
The speed rating of the geared head output shaft(s).CWHK
Geared Head Output Shaft Speed Rating:
36.000 single revolutions per minute single end
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A2 first style single end and a14 second style single end
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unf single end
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead