부품 번호 JHDX45A

Diesel Engine Generator Set

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards
부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
jhdx45a
비무장화:
No
수명:
측정 단위:
NIIN:
006781737
NSN
국가 주식 번호:
6115-00-678-1737 6115006781737
TXT
묘사:
Diesel Engine Generator Set
INC
INC
아이템 이름 코드:
00476
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Liquid
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Skid
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
84.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
59.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
36.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz and 400.0 hertz
MRC:
The means of cooling used to maintain the required operating temperature of the item.AENK
Cooling Method:
Radiator
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
An indication of whether or not winterization is included.AMWJ
Winterization Feature:
Included
MRC:
The alternating current for which the item is rated,expressed in watts.AYGY
Ac Wattage Rating:
45.0 kilowatts and 45.0 kilowatts
MRC:
The total electrical line to line voltage for which the item is rated,expressed in volts.AYHB
Line To Line Voltage In Volts:
416.0 and 208.0
MRC:
The total electrical line to neutral voltage for which the item is rated,expressed in volts.AYHC
Line To Neutral Voltage In Volts:
240.0 and 120.0
MRC:
The ratio between actual rated power,and power required by a specified load applied to the item,expressed in percent.AYHD
Power Factor In Percent:
0.8 and 0.8
MRC:
Indicates the type of excitor provided.AYHE
Excitor Type:
Separately excited
MRC:
An indication of whether or not an excitor is included.AYHF
Excitor:
Included
MRC:
The means used to start the prime mover.AYQZ
Prime Mover Starting Method:
Electric motor
MRC:
The total electrical voltage required for cranking the item,expressed in volts.AYSA
Cranking Voltage In Volts:
24.0
MRC:
An indication of whether or not an automatic starting feature is provided.AZBM
Automatic Starting Feature:
Not provided
MRC:
Indicates the type of housing provided.AZCB
Housing Type:
Inclosed
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated,expressed in degrees celsius.AZCL
Ambient Tempurature In Deg Celsius:
-53.9 and 51.7
MRC:
The permissible temperature increase for continuous operation,at which the item is rated,expressed in degrees celsius.AZCM
Tempurature Rise Rating In Deg Celsius For Continuous Operation:
75.0
MRC:
An indication of whether or not radio interference suppression is included.AZKT
Radio Interference Suppression:
Not included
MRC:
The number of alternating current phases.FAAZ
Phase:
Three and three
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
2 type

{lang[cimilar]} Diesel Engine Generator Sets

« Generators and Generator Sets, Electrical {lang[catalog]}
지금 비교»
맑다 | 숨기다