MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
20.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
10.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
15.000 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Portable
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Electron tube
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
100.0 kilohertz operating channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
100.0 megahertz operating channel err-100
MRC:
Indicates the type of frequency adjustment included in the item.BHTD
Frequency Adjustment Type:
Continuous
MRC:
The amount of allowable variation relative to a specified frequency level,expressed in decibels.BHTG
Variation Frequency Rating In Decibels:
0.2
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
20.0
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
3.0
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
120.0 watts input
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
0.350 volts output
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms operating channel
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
50.000 pulses per second operating channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
60.000 pulses per second operating channel err-100
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
50.0 1st voltage
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
60.0 2nd voltage
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
230.0 2nd voltage err-100
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
115.0 1st voltage