TXT
묘사:
Fluid Pressure Regulating Valve
First End Flange Outside Diameter:
140.0 millimeters
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight thru
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Oil
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Plain face flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Plain
MRC:
The style designation indicating the configuration that most nearly corresponds to the shape of the end flange.ACKT
First End Flange Shape Style:
Round w/ bolt holes
MRC:
A measurement of the smallest dimension of the first end flange, in distinction from length or width.ACKU
First End Flange Thickness:
16.0 millimeters
MRC:
The number of bolt holes provided on the item.ACKZ
First End Bolt Hole Quantity:
4
MRC:
The length of a straight line which passes through the center of a bolt hole,and terminates at the circumference.ACLA
First End Bolt Hole Diameter:
19.0 millimeters
First End Bolt Circle Diameter:
105.0 millimeters
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
Face To Face Distance:
220.0 millimeters
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Rubber, synthetic
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Automatic single stage
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Spring
MRC:
The set /nonadjustable/ pressure of the media on the outlet side.AEWA
Outlet Pressure Setting:
4.0 kilograms per square centimeter
MRC:
An indication of whether or not a filter is included.AEWF
Filter:
Not included
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Strategic sealift conversion ships class