TXT
묘사:
Refrigeration Condenser
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 123.000 inches and 124.000 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water
MRC:
The element,compound,or mixture of which the head is fabricated,excluding any surface treatment.ARGE
Head Material:
Iron
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
100
MRC:
The type of water with which the item is designed to be used.AWCD
Water For Which Designed:
Fresh
MRC:
The number of passes provided.AWGE
Pass Quantity:
2
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Copper
MRC:
A measurement of the longest dimension of a tube between the inside faces of the tube sheets,in distinction from width.AWGK
Tube Effective Length:
9.000 feet
MRC:
An indication of whether of not the tube(s) is provided with fins.AWGL
Tube Fin:
Provided
MRC:
The number of water connections provided.AWKT
Water Connection Quantity:
2
MRC:
Indicates the type of water connection/s/.AWKW
Water Connection Type:
Flange
MRC:
The maximum internal pressure,determined by destruction tests at which the item can be expected to rupture.AWWH
Water Side Test Minimum Pressure:
200.0 pounds per square inch
MRC:
Indicates the type of cooling.AYTS
Cooling Type:
Water
MRC:
The rated capacity of water flow moved through the item.CWTS
Water Flow Rate:
280.0 gallons per minute