MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
250.0 hertz blank
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
1.0 kilohms blank
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
730.0 ohms blank
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance blank
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
3.5 blank
MRC:
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
Specified Frequencies Of Discrimination Per Function:
150.00 hertz blank and 200.00 hertz blank and 285.00 hertz blank and 360.00 hertz blank
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Metal
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
200.00 hertz blank and 285.00 hertz blank
MRC:
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 blank and 45.0 blank
MRC:
The minimum and maximum values of frequency,per function,between which the voltage standing wave ratio is specified.CRBN
Voltage Standing Wave Ratio Frequency Limits Per Function:
200.0 hertz blank and 285.0 hertz blank