TXT
묘사:
Overvoltage Absorber
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
1 and 1
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Solder lug and threaded stud
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.703 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The element,compound,or mixture of which the covering is fabricated.ACKG
Covering Material:
Plastic, epoxy resin
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
Between 0.550 inches and 0.560 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Terminal
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
One solder lug a/a length and one thd stud 0.422 in. Min 0.453 in. Maximum long with 0.250-28 unf-2a thds; terminals are axially located
MRC:
An indication of whether or not a polarization feature is included.ALPY
Polarization Feature:
Included
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
35.0
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
High shock proof and humidity proof and salt air proof
MRC:
Indicates the type of protective covering provided.APZX
Protective Covering Type:
Coating
MRC:
An indication of whether or not a shunt capacitor is included.AQCT
Shunt Capacitor:
Not included
MRC:
The element,compound,or mixture of which the element is fabricated,excluding any surface treatment.AQCW
Element Material:
Any acceptable
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
43.0