TXT
묘사:
Waveguide Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Internal, rectangular external, rectangular
MRC:
The number of flanges provided with the item.AHSF
Flange Quantity:
6
Flange Inside Width:
0.705 inches fifth flange and 0.707 inches fifth flange
Flange Inside Width:
0.705 inches first flange and 0.707 inches first flange
Flange Inside Width:
0.705 inches fourth flange and 0.707 inches fourth flange
Flange Inside Width:
0.705 inches second flange and 0.707 inches second flange
Flange Inside Width:
0.705 inches third flange and 0.707 inches third flange
Flange Inside Height:
0.394 inches third flange and 0.396 inches third flange
Flange Inside Height:
0.394 inches fifth flange and 0.396 inches fifth flange
Flange Inside Height:
0.394 inches first flange and 0.396 inches first flange
Flange Inside Height:
0.394 inches fourth flange and 0.396 inches fourth flange
Flange Inside Height:
0.394 inches second flange and 0.396 inches second flange
Flange Outside Width:
1.298 inches second flange and 1.328 inches second flange
Flange Outside Width:
1.298 inches third flange and 1.328 inches third flange
Flange Outside Width:
1.298 inches fifth flange and 1.328 inches fifth flange
Flange Outside Width:
1.298 inches first flange and 1.328 inches first flange
Flange Outside Width:
1.298 inches fourth flange and 1.328 inches fourth flange
Flange Outside Height:
1.298 inches fourth flange and 1.328 inches fourth flange
Flange Outside Height:
1.298 inches second flange and 1.328 inches second flange
Flange Outside Height:
1.298 inches third flange and 1.328 inches third flange
Flange Outside Height:
1.298 inches fifth flange and 1.328 inches fifth flange
Flange Outside Height:
1.298 inches first flange and 1.328 inches first flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.090 inches fifth flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.298 inches first flange and 0.328 inches first flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.298 inches fourth flange and 0.328 inches fourth flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.298 inches second flange and 0.328 inches second flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.298 inches third flange and 0.328 inches third flange
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.118 inches sixth flange all connection facilities and 0.123 inches sixth flange all connection facilities
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.142 inches fifth flange all connection facilities and 0.147 inches fifth flange all connection facilities
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.144 inches first flange all connection facilities and 0.147 inches first flange all connection facilities
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.144 inches fourth flange all connection facilities and 0.147 inches fourth flange all connection facilities
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.144 inches second flange all connection facilities and 0.147 inches second flange all connection facilities
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.144 inches third flange all connection facilities and 0.147 inches third flange all connection facilities
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.15
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.30
Waveguide Outside Width:
Between 0.699 inches and 0.705 inches
Waveguide Inside Width:
Between 0.620 inches and 0.625 inches
Waveguide Inside Height:
Between 0.309 inches and 0.314 inches
Waveguide Outside Height:
Between 0.388 inches and 0.394 inches
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
4 unthreaded hole all flanges all connection facilities
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Cover type fifth flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Cover type first flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Cover type fourth flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Cover type second flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Cover type third flange
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy all tubing segment and flange
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Antennas, waveguides, and related equipment