부품 번호 G-202

Radiographic And X-ray Apparatus

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 195699.27 and 255914.43 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
g-202
비무장화:
No
수명:
N/A
측정 단위:
1 EA
NIIN:
011893986

부품 정보
X-ray apparatus: high capacity radiographic and fluroscopic

NSN
국가 주식 번호:
6525-01-189-3986 6525011893986
TXT
묘사:
Radiographic And X-ray Apparatus
INC
INC
아이템 이름 코드:
06321
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Motor
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Adj non-skid footrest-1; compression-immobilizing device-1; head clamp-1; patient grasp handles-1; skidproof patient step-1; shoulder rest-1
MRC:
Indicates the design type of the item.APGF
Design Type:
Stationary
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
2
MRC:
The value of electrical energy for which the item is rated.ARQE
Electric Power Rating:
45000.0 watts
MRC:
Indicates the type of tube provided.AWGH
Tube Type:
Double focus, rotating anode fluoroscopic and double focus, rotating anode radiographic
MRC:
Indicates the type of table provided.BNBB
Table Type:
Tilting
MRC:
Indicates the type of rectification provided.BPKZ
Rectification Type:
Full-wave
MRC:
The means of cooling used to maintain the required operating temperature of the tube.CLPG
Tube Cooling Method:
Air
MRC:
Indicates the type of mount utilized to support the tube.CLPH
Tube Mounting Type:
Table and tube stand
MRC:
Indicates the type of mount utilized to support the tube stand.CLPR
Tube Stand Mounting Type:
Floor to ceiling
MRC:
The minimum and maximum limits of tilt for which the item is designed.CLPT
Err Default:
Err default
MRC:
An indication of whether or not a bucky diaphragm is included.CLPW
Err Default:
Err default
MRC:
The means used for rectifying the transformer.CLQD
Transformer Rectification Method:
Self-rectifying
MRC:
The power output for which the transformer is rated.CLQF
Transformer Output Capacity:
To 300 ma at 150 kv peak
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
190.0 and 270.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
50/60 hz, ac; w/rotating anode; designed for use w/image intensifier; c/o solid state control unit, transformer w/solid state rectifiers; 45 ft radiographic and 25 ft fluoroscopic high voltage cable, collimator, 24 by 24 cm front end-loading, spot-film device; bucky diaphragm, floor-to ceiling floor mt, and vert cassette holder

{lang[cimilar]} Radiographic And X-ray Apparatus

« Imaging Equipment and Supplies: Medical, Dental, Veterinary {lang[catalog]}
지금 비교»
맑다 | 숨기다