부품 정보
Requested name dc interlock; unit contains 5 mercury relays; dc output r elay contact 50 a; dc output sense relay contact 1 a; current flow through control lines less than 200 milliamps; ac input 120 vac at 3 a max; simplifies the safety interlock mechanism required between the dc sources and operator's test panel; provides independent output relay control of each source; disconnects outputs of the dc sources and their sense lines; t.O. 33a1-3-583-1
TXT
묘사:
Electrical Test Set Subassembly
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
18.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.000 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Power supply test station, 6625013991759
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
Indicates the type and number of components which make up the assembly or subassembly.CXCK
Component Type And Quantity:
2 plug and 20 relay and 2 transformer and 4 jack