MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Rejection groove type					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						1.500 inches 					
				 
							
					
						MRC:
						A measurement of the longest straight line across a circular cross-sectional plane.ADAV
					 
					
						Overall Diameter:
					
					
						0.406 inches 					
				 
							
					
						MRC:
						The maximum direct current,or root mean square current at rated frequency,that an item will carry continuously.AEBJ
					 
					
						Continuous Current Rating In Amps:
					
					
						10.000					
				 
							
					
						MRC:
						The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
					 
					
						Maximum Voltage Rating In Volts:
					
					
						600.0 ac					
				 
							
					
						MRC:
						Indicates the type of over-current conditions that an item is designed to withstand indicated by the speed of circuit interruption.AFXF
					 
					
						Circuit Over-current Interruption Type:
					
					
						Time delay					
				 
							
					
						MRC:
						The means in which the item signals the interruption of a circuit.AFXH
					 
					
						Interruption Indicator Method:
					
					
						Opaque body					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Ac controller p/n 8722372-00 onboard 225 ft wlb coast guard vessels					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Nonrenewable fusible element					
				 
							
					
						MRC:
						The time elapsing before circuit interruption of an item operated at a specified percent of its normal current rating,expressed in seconds.CQPB
					 
					
						Circuit Over-current Interruption Delay Time In Seconds:
					
					
						12.0 200 pct of current rating					
				 
							
					
						MRC:
						The maximum rated current at which the item will interrupt or short circuit,expressed in amperes.CSQN
					 
					
						Short-circuit/interrupt Current Rating In Amps:
					
					
						200000.0