MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
11.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.880 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.812 inches
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 2nd operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 1st operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
115.0 ac pounds per hour wet 2nd operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
230.0 ac pounds per hour wet 1st operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
24.0 dc volts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-12.0 dc volts 4th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-5.0 dc volts 3rd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
5.0 dc volts 2nd power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 1st operating power rqmt and 440.0 hertz 1st operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 2nd operating power rqmt and 440.0 hertz 2nd operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+40.0 degrees celsius
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 1st power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 2nd power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 3rd power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 4th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
1.2 dc amperes 3rd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
1.2 dc amperes 4th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
5.0 dc amperes 1st power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
9.0 dc amperes 2nd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 2nd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 3rd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 4th power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 1st power output
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Convection