MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
8.35 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.3 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.5 inches
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Digital display
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Hand held
MRC:
Indicates the type of display provided.BFQN
Display Type:
Light emitting diode (l.E.D.).
MRC:
The number of digits displayed.BFQP
Display Digit Quantity:
U5
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-30.0 to 55.0 millivolts, af 1st indicator single range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
P40 1st indicator single range
MRC:
The hue or tint of the display.CTQH
Display Color:
Red 1st indicator single range
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
1 clamp-on
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Portable