부품 정보
Three switches, actuated at23.500 in., 16.880 in., 4.880 in. From top of tank
TXT
묘사:
Liquid Level Switch
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
110.0 volts
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
220.0 volts 2nd operating power rqmt
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
50.0 volts 4th operating power rqmt
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
6.0 volts 3rd operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.875 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Buoyancy
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
200.0 milliamperes load
MRC:
The amount of voltage for which the item is designed to withstand at the maximum rated current.APGY
Voltage Rating At Maximum Rated Current:
50.0 volts
MRC:
The number of floats provided.AWAE
Float Quantity:
3
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between 0.0 degrees celsius and 85.0 degrees celsius
MRC:
The means of attaching the item.AXGY
Mounting Method:
Thread
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Vertical
MRC:
The maximum continuous current which must not be exceeded in order to avoid damage to the item.BJKC
Maximum Current Rating:
200.0 milliamperes load
MRC:
The designation that identifies the schematic diagram of the contact arrangement.BJKD
Contact Arrangement:
Spst, normally closed, dry
MRC:
An indication of whether or not a relay is included.BJKG
Relay:
Not included
MRC:
Indicates the type of liquid(s) for which the item is designed.BJKH
Liquid Type For Which Designed:
Demineralized water
MRC:
The distance of the effective travel of the float.BJKN
Float Effective Travel:
0.500 inches
MRC:
The mounting dimensions of the item.BJKP
Mounting Dimensions:
Mtd by 3/8-18 npt thd shaft end
MRC:
A measurement of the longest dimension from the mounting surface to the end of the item,which is designed to be inserted into the tank.BJKQ
Tank Insertion Length:
25.880 inches
MRC:
The number of alternating current phases.FAAZ
Phase:
Single/three