부품 번호 FA4072

Band Pass Filter

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 14232.075 and 18611.175 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
fa4072
비무장화:
Yes - DEMIL/MLI
수명:
N/A
측정 단위:
1 EA
NIIN:
013723576
NSN
국가 주식 번호:
5915-01-372-3576 5915013723576
TXT
묘사:
Band Pass Filter
INC
INC
아이템 이름 코드:
00209
INC
COM
컴플라이언스:
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.900 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 3.940 inches and 3.960 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.870 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.140 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 3.367 inches and 3.383 inches
MRC:
The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
2.150 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+70.0 degrees celsius
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
62.5 hercules no.5599.1 pulses per second61.88 hercules no.5599.1 two phase to two phase60.94 hercules no.5599.1 two phase to three phase60.0 hercules no.5599.1 hertz
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms 1st band pass50.0 ohms 2nd band pass50.0 ohms 3rd band pass50.0 ohms 4th band pass
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms 1st band pass50.0 ohms 2nd band pass50.0 ohms 3rd band pass50.0 ohms 4th band pass
MRC:
The ratio of the maximum to the minimum voltage of the standing wave per function. the larger relative portion is given,the lower value having an implied /not given/ value of one /unity/.AHBZ
Voltage Standing Wave Ratio Per Function:
1.7 1st band pass1.7 2nd band pass1.7 3rd band pass1.7 4th band pass
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Gaussian response and active and shock resistant and fungus resistant and moisture resistant and salt water resistant
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 1st band pass3.0 2nd band pass3.0 3rd band pass3.0 4th band pass
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
4 pin input 1st function4 pin output 2nd function
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Metal
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
59.97 megahertz 1st band pass and 65.04 megahertz 1st band pass59.97 megahertz 2nd band pass and 63.78 megahertz 2nd band pass59.98 megahertz 3rd band pass and 61.89 megahertz 3rd band pass57.14 megahertz 4th band pass and 62.86 megahertz 4th band pass
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular terminal/terminals on opposite surfaces

{lang[cimilar]} Band Pass Filters

« Filters and Networks {lang[catalog]}
지금 비교»
맑다 | 숨기다