TXT
묘사:
Liquid Level Switch
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
12.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
28.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
Between 3.484 inches and 3.516 inches
MRC:
The identifying numeric code of the originator that controls or manufactures the electrical connector receptacle.AEEE
Connector Manufacturer Code:
96906
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Buoyancy
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Connector receptacle
MRC:
The specification,standard,or manufacturer's number or symbol used to identify the connector.AGBG
Connector Identification:
Ms3402d-10sl-3p
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The amount of voltage for which the item is designed to withstand at the maximum rated current.APGY
Voltage Rating At Maximum Rated Current:
28.0 volts
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between 28.0 degrees fahrenheit and 150.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Vertical
MRC:
The designation that identifies the schematic diagram of the contact arrangement.BJKD
Contact Arrangement:
Single throw, normally closed
MRC:
An indication of whether or not a relay is included.BJKG
Relay:
Not included
MRC:
Indicates the type of liquid(s) for which the item is designed.BJKH
Liquid Type For Which Designed:
Sea water
MRC:
The mounting dimensions of the item.BJKP
Mounting Dimensions:
Mtd by six 0.266 in. Diameter holes equally spaced on a 2.375 in. Diameter bolt circle
MRC:
The number of alternating current phases.FAAZ
Phase:
Single