MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
2.800 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
3.020 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
3.000 inches
MRC:
The length of a straight line which passes through the center of a hole,and terminates at the circumference.AAUB
Hole Diameter:
0.093 inches single end and 0.100 inches single end
MRC:
A measurement between specified points of the hole,in distinction from height.AAZQ
Hole Depth:
0.4430 inches single end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.433 inches single end and 0.443 inches single end
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc input
Hole Center To Shaft End Distance:
0.110 inches single end and 0.140 inches single end
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise single end or counterclockwise single end
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Open
MRC:
Indicates the specific arrangement in which wire is wound on a form or is formed by winding.AXCP
Winding Type:
Permanent magnet
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 unthreaded hole
MRC:
The acceptable time limits for the item.BFLT
Time Interval:
1.0 minutes on and 9.0 minutes off
MRC:
The drive shaft position as related to the armature axis.BFLY
Geared Head Output Shaft Alignment Position:
Offset below parallel to shaft axis single end
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Ambient air
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
Load
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Commercial
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Vertical mounting position and horizontal mounting position
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
1.020 inches single end
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
-28.0 ambient degrees celsius and 85.0 ambient degrees celsius
MRC:
The length of a straight line which passes through the center of a mounting facility circle,and terminates at the circumference.CWFQ
Mounting Facility Circle Diameter:
2.625 inches
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
0.130 single output
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
24.0 line to neutral single input
MRC:
The speed rating of the geared head output shaft(s).CWHK
Geared Head Output Shaft Speed Rating:
32.000 single revolutions per minute single end
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A13 single style single end
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 solder lug