MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk
MRC:
Indicates the type of housing on the item that accommodates the stem packing or spring.ADSR
Bonnet Type:
Inside screw
MRC:
The means by which the bonnet is attached to the item.ADST
Bonnet Attachment Method:
Threaded
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
275.0 degrees fahrenheit single response
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Manual
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded internal boss 1st end
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Bulkhead
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Bonnet packing
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
4000.0 pounds per square inch single response
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy body or steel body
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy seat
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel flow control device
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel stem
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Fuel/oil, hydrocarbon single response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090