부품 정보
Txv valve or thermostatic expansion valve
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Refrigerant
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded external tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Flared
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACLH
First End Outside Diameter Tube Accommodated:
0.375 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
30.000 inches
MRC:
Indicates the type of control by which the valve is expanded.AFKK
Valve Expansion Control Type:
Thermostatic
MRC:
Indicates the type of connection in the valve body for connecting the equalizer line.AFKV
Valve Equalizer Connection Type:
Solder tube
MRC:
The length of a straight line which passes through the center of the valve equalizer connection,and terminates at the circumference.AFKW
Valve Equalizer Connection Diameter:
0.250 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Carrier corporation air conditioner
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
dimensions length 3.312 inches, height 2.812 inches; has linear mechanical actuator and superheat sensing bulb, connections are sae 3/8 inch flare; external equalizer connection is 0.250 odf solder.