부품 정보
Indicatior, differential pressure circular dial
TXT
묘사:
Diff Fluid Flow Indicating Meter
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Flush
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the circumference.ABMZ
Diameter:
5.593 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
6.269 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Liquid
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum
MRC:
The general outside configuration of the case.ANRX
Case Shape:
Round
MRC:
An indication of the presentation range of the scale.ASPF
Scale Presentation Range:
0-100 at 90
MRC:
The smallest numeric figure the item will register.AXEA
Smallest Increment Indicated:
1.0
MRC:
The hue or tint of the inscription(s) and/or that portion of the scale which surrounds the inscription on the scale.BGKZ
Scale Inscription/background Color:
Background color: white
MRC:
The maximum differential pressure which the item is capable of withstanding without evidence of deformation or other damage.CPYY
Maximum Differential Pressure:
Differential pressure range: tulse range 45; dial range 0-15; static press: 67.5
MRC:
An indication of whether or not a totalizing integrator register is included.CPZB
Totalizing Integrator Register:
Not included
MRC:
Designates the size of the inlet connection included on the item.CPZD
Inlet Connection Size:
1/4-npt
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Pressure system material: phosphore bronze bourdon tube; operating ambient temp. Range +40? To 145?F; connection location: back