부품 정보
						Time delay is dial calibrated in linear increments;  weapon system essential
					 
				 
						
			
				
					TXT
				
				
					묘사:
				
				
					Electromagnetic Relay				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						4.520 inches 					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Length:
					
					
						0.750 inches  single mounting facility					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						2.570 inches 					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Electrical;  mts;  moored training ship					
				 
							
					
						MRC:
						The number of individual /not electrically connected/ windings.AKDX
					 
					
						Winding Quantity:
					
					
						1					
				 
							
					
						MRC:
						The number of coils included on the item.APCN
					 
					
						Coil Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of duty provided.APNP
					 
					
						Duty Type:
					
					
						Continuous					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						6 bracket single mounting facility					
				 
							
					
						MRC:
						The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
					 
					
						Nonpile-up Main Contact Arrangement:
					
					
						2 pole,  double throw,  one position momentary					
				 
							
					
						MRC:
						The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
					 
					
						Criticality Code Justification:
					
					
						Feat					
				 
							
					
						MRC:
						The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
					 
					
						Time Delay:
					
					
						0.50 seconds  adjustable release time and 5.00 seconds  adjustable release time					
				 
							
					
						MRC:
						The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
					 
					
						Operating Voltage Rating And Type At Specificationified Temp:
					
					
						125.0 volts dc 25 degrees celsius single winding					
				 
							
					
						MRC:
						The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
					 
					
						Main Contact Load Current Rating At Maximum Rated Voltage:
					
					
						1.0 amperes dc resistive load					
				 
							
					
						MRC:
						The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
					 
					
						Main Contact Maximum Voltage Rating In Volts:
					
					
						125.0 dc					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						8 screw all functions