부품 정보
2-way direct acting solenoid-operated directional poppet valve
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The position of the moving member/s/ controlling flow through the valve with the solenoid in the de-energized position.ADSK
Flow Control Device Normal Operation Position:
Closed
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Submarine barracuda
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Plain (screw-in cartridge) 1st end
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded cartridge 1st end
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Horizontal or vertical
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
5000.0 pounds per square inch single response
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Supplied without coil; cavity t-13a
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Oil, hydraulic single response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Screw-in cartridge