부품 번호:
drfp-ns3503ccw-1028jf
TXT
묘사:
Centrifugal Fan Assembly
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The different speeds at which the item may be operated.ABBB
Speed Adjustments:
Single speed
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
6.624 inches
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the circumference.ABMZ
Diameter:
3.500 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
6.250 inches
MRC:
The temperature of the medium surrounding an item at which it can be operated continuously at full rated power.AEHY
Ambient Tempurature At Full Rated Power:
-55.0 degrees celsius and 75.0 degrees celsius
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
5650.0
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Wire lead
Outlet Inside Width:
2.719 inches
Outlet Inside Height:
2.500 inches
MRC:
The static pressure measured at the air flow rate specified.AJLY
Static Pressure At Specificationified Air Flow Rate:
0.0 inches of water
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Direct
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 flange
MRC:
The direction of rotation for which the item is designed.AYSY
Rotation Direction For Which Designed:
Counterclockwise
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Nonsparking
MRC:
The rated capacity of air flow moved through the item.CQKX
Air Flow Rate:
280.0 cubic feet per minute
MRC:
Indicates the location of the outlet on the item.CRWJ
Outlet Location:
Bottom or top
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
115.0 ac
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
0.020 horsepower
MRC:
Indicates the type of bearing/s/ provided on the prime mover drive shaft.CWLY
Prime Mover Drive Shaft Bearing Type:
Ball
MRC:
The direction in which the item discharges during operation.CXCB
Discharge Direction:
Angular down and angular up and horizontal and vertical down and vertical up
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
6.880 inches
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel
MRC:
A numeric value which represents a positive whole value without regard to any unit of measure.NMBR
Quantity:
1
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Enamel housing
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Zinc blade
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Fixed, rectangular outlets
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
10001-28552 83 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)