TXT
묘사:
Power Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
Winding Shielding Method:
Internal shield grounded to inclosure and core single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
8.250 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
5.000 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
7 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange single group and unthreaded hole single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange and unthreaded hole single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 1 secondary single component
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary and 1 secondary single component
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
456.0 amperes ac single component single secondary and 477.0 amperes ac single component single secondary and 505.0 amperes ac single component single secondary and 542.0 amperes ac single component single secondary and 592.0 amperes ac single component single secondary and 660.0 amperes ac single component single secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
456.0 amperes ac and 477.0 amperes ac and 505.0 amperes ac and 542.0 amperes ac and 592.0 amperes ac and 660.0 amperes ac single component single secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
0.66 ac pounds per hour wet single component single secondary and 1.91 ac pounds per hour wet single component single secondary and 1.94 ac pounds per hour wet single component single secondary and 1.01 ac pounds per hour wet single component single secondary and 1.08 ac pounds per hour wet single component single secondary and 1.18 ac pounds per hour wet single component single secondary and 1.32 ac pounds per hour wet single component single secondary and 325.00 ac pounds per hour wet single component single secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
0.66 ac volts and 1.91 ac volts and 1.94 ac volts and 1.01 ac volts and 1.08 ac volts and 1.18 ac volts and 1.32 ac volts and 325.00 ac volts single component single secondary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 threaded stud and 8 turret