부품 정보
Direct immersion heater
TXT
묘사:
Engine Coolant Heater
MRC:
The maximum output of the unit,expressed in british thermal units per hour.ABAK
Heat Delivery Rate In Btu Per Hour:
Not rated
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Detroit diesel models 3-53, 4-53, 3-71, and 4-71
MRC:
An indication of whether or not a mounted heater switch is included.ARHR
Mounted Heater Switch:
Not included
MRC:
Indicates whether or not an automatic temperature control is included.ARHS
Automatic Tempurature Control:
Included
MRC:
An indication of the power source for which the item is designed.ARHZ
Power Source For Which Designed:
Electricity
MRC:
The rated power that the heating element can safely consume or provide,measured in watts.ARJB
Heating Element Wattage:
750.0
MRC:
The means used for circulating the coolant.ARJC
Coolant Circulation Method:
Natural
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
120.0 ac
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
120.0
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Mounts in football shaped plate on block
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Electrical element heats coolant in block