부품 정보
Built-in transformer-rectifier for conversion of 115.000 v 60.000 cycles ac
TXT
묘사:
Gas-particulate Filter Unit
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
Indicates the type of filter used with the item.ALTR
Filter Type:
Individual gas/particulate
MRC:
The amount of operating voltage,expressed in volts.APHA
Operating Voltage In Volts:
24.000
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor
MRC:
A measurement of the rate of filtration.BTLT
Filtration Rate:
12.000 cubic feet per minute
MRC:
The combined group of letters,numerals,and/or symbols which compose the assigned model number of the gas filter.CGSH
Err Default:
Err default
MRC:
The combined group of letters,numerals,and/or symbols which compose the assigned model number of the gas filter.CGSH
Gas Filter Model Number:
M12
MRC:
The specification and/or standard used to limit the element,compound,or mixture of the gas filter.CGSJ
Err Default:
Err default
MRC:
The specification and/or standard used to limit the element,compound,or mixture of the gas filter.CGSJ
Gas Filter Specification/std:
Edgewood arsenal, pd197-54-503
MRC:
The combined group of letters,numerals,and/or symbols which compose the assigned model number of the particulate filter.CGXB
Particulate Filter Model Number:
M13
MRC:
The specification and/or standard used to limit the element,compound,or mixture of the particulate filter.CGXC
Err Default:
Err default
MRC:
The specification and/or standard used to limit the element,compound,or mixture of the particulate filter.CGXC
Particulate Filter Specification/std:
Mil, mil-f-52011
MRC:
The individual protective device and the number the item is designed to accommodate.CGXF
Err Default:
Err default
MRC:
The individual protective device and the number the item is designed to accommodate.CGXF
Individual Protective Device And Quantity Accommodated:
6 headpiece
MRC:
An indication of whether or not a headpiece is included.CGXH
Err Default:
Err default
MRC:
An indication of whether or not a headpiece is included.CGXH
Headpiece:
Included
MRC:
An indication of whether or not an air heater(s) is included.CGXJ
Err Default:
Err default
MRC:
An indication of whether or not an air heater(s) is included.CGXJ
Air Heater:
Not included
MRC:
The designed use of the blower assembly.CGXK
Blower Assembly Usage Design:
Indoor
MRC:
An indication of whether or not an installation kit is included.CGXM
Installation Kit:
Not included
MRC:
An indication of whether or not a tool kit is included.CGXN
Tool Kit:
Not included
MRC:
An indication of whether or not provisions to suppress electromagnetic interference /emi/ are provided.CRFK
Electromagnetic Interference Suppression:
Provided