부품 정보
						Also detects v chemical agent andcan be used on vehicles
					 
				 
						
			
				
					TXT
				
				
					묘사:
				
				
					Automatic Chemical Agent Alarm				
			 
			
							
										
					
						MRC:
						The alternating current rating for which the item is rated,expressed in amperes.ACUS
					 
					
						Alternating Current Rating In Amps:
					
					
						1.5					
				 
							
					
						MRC:
						The value,or range of values,of root mean square potential for which the item is rated.ACYN
					 
					
						Ac Voltage Rating:
					
					
						Between 110.0 volts and 220.0 volts 					
				 
							
					
						MRC:
						The value,or range of values,of direct current potential for which the item is rated.ACYR
					 
					
						Dc Voltage Rating:
					
					
						28.0 volts  and 28.0 volts 					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						Between 50.0 hertz and 400.0 hertz 					
				 
							
					
						MRC:
						Indicates the designed use of the item.ALBY
					 
					
						Usage Design:
					
					
						Field					
				 
							
					
						MRC:
						The name and number of components which make up the item.ALPC
					 
					
						Component And Quantity:
					
					
						Alarm unit, chemical agent automatic alarm, m42, /fsn6665-859-2215/ 1! Battery, dry /ba3517/, /fsn6135-450-3528/ 1! Battery, dry /ba3202/, /fsn6135-935-8738/ 4! Detector unit, chemical agent automatic alarm, m43, /fsn6665-859-2201/ 1! Installation kit, chemical agent automatic alarm, for truck, utili type 1/4 ton /fsn6665-479-2716/ 1! Mounting kit, chemical agent automatic alarm, m228, high profile/fsn6665-859-2212/ 1! Power supply, chemical agent automatic alarm, m10, /fsn6665-859-2225/ 1! Refill kit, chemical agent automatic alarm, m229, /fsn6665-859-2214/ 1					
				 
							
					
						MRC:
						The name and number of components which make up the item.ALPC
					 
					
						Component And Quantity:
					
					
						Alarm unit, chemical agent automatic alarm, m42, /fsn6665-859-2215/ 1;  battery, dry /ba3517/, /fsn6135-450-3528/ 1;  battery, dry /ba3202/, /fsn6135-935-8738/ 4;  detector unit, chemical agent automatic alarm, m43, /fsn6665-859-2201/ 1;  installation kit, chemical agent automatic alarm, for truck, utili type 1/4 ton /fsn6665-479-2716/ 1;  mounting kit, chemical agent automatic alarm, m228, high profile/fsn6665-859-2212/;  power supply, chemical agent automatic alarm, m10, /fsn6665-859-2225/ 1;  refill kit, chemical agent automatic alarm, m229, /fsn6665-859-2214/ 1					
				 
							
					
						MRC:
						An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
					 
					
						Internal Battery Accommodation:
					
					
						Not included					
				 
							
					
						MRC:
						Indicates the designed use of the item.ALXZ
					 
					
						Specific Usage Design:
					
					
						Specific usage design samples air continously, which is automatically heated/if necessary/, filtered, drawn into the detector cell, where it passes through the electrolyte solution. If v or g agents are present, the galvanic voltage produced by the cell increases. The change is amplified by the electronic module which sounds the detector horn and/or activated a flashing light, applies power to the remote terminals and stops the pump motor. The horn will continue to sound and/or the light flash until the detector is reset or disconnected gy the operator. The system is designed for manpack, fixed emplacement and vehicular use. Dry cell battery is used for manpack application. M10 power supply is used for fixed emplacement appl. Mounting kit and installation kit are used for 1/4 ton utility truck appl.					
				 
							
					
						MRC:
						Indicates the type of device used to register the condition(s).AMKD
					 
					
						Indicator Type:
					
					
						Flashing red light and horn					
				 
							
					
						MRC:
						Indicates the design type of the item.APGF
					 
					
						Design Type:
					
					
						Nontripod mounting					
				 
							
					
						MRC:
						An indication of the media detected by the item.BRQN
					 
					
						Media Detected:
					
					
						G chemical agent					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Single