부품 정보
Also detects v chemical agent
TXT
묘사:
Automatic Chemical Agent Alarm
MRC:
The alternating current rating for which the item is rated,expressed in amperes.ACUS
Alternating Current Rating In Amps:
1.5
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 110.0 volts and 220.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
28.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 400.0 hertz
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Field
MRC:
The name and number of components which make up the item.ALPC
Component And Quantity:
Alarm unit, chemical agent automatic alarm, m42 /fsn6665-859-2215/1, battery, dry /ba3517/ fsn6135-450-3528/ 1, battery, dry /ba3202/, /fsn6135-935-8738/ 4, detector unit, chemical agent automatic alarm, m43 /fsn6665-859-2201/ 1, refill kit, chemical agent automatic alarm, m229 /fsn6665-859-2214/ 1, power suppy, chemical agent automatic alarm, m10 /fsn6665-859-2225/ 1
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
Indicates the designed use of the item.ALXZ
Specific Usage Design:
Samples air continuously, which is automatically heated /if necessary/, filtered, drawn into the detector cell, where it passed through the electrolyte solution! If v or g agents are present, the galvanic voltage produced by the cell increases, the change is amplified by the electronic module which sounds the detector horn and/or activates a flashing light, applies power to the remote terminals and stops the pump motor. The horn will continue to sound and/or the light flash until the detector is reset or disconnected by the operator. The system is designed for manpack or fixed emplacement operation using dry cell battery for manpack and mid power supply unit for fixed emplacement use
MRC:
Indicates the designed use of the item.ALXZ
Specific Usage Design:
Samples air continuously, which is automatically heated/if necessary/, filtered, drawn into the detector cell, where it passed through the electrolyte solution; if v or g agents are present, the galvanic voltage produced by the cell increases, the change is amplified by the electronic module which sounds the detector horn and/or activates a flashing light, applies power to the remote terminals and stops the pump motor. The horn will continue to sound and/or the light flash until the detector is reset or disconnected by the operator. The system is designed for manpack or fixed emplacement operation using dry cell battery for manpack and mid power supply unit for fixed emplacement use
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Flashing red light and horn
MRC:
Indicates the design type of the item.APGF
Design Type:
Nontripod mounting
MRC:
An indication of the media detected by the item.BRQN
Media Detected:
G chemical agent
MRC:
The number of alternating current phases.FAAZ
Phase:
Single