TXT
묘사:
Immer Electrical Heating Element
MRC:
The style designation indicating the configuration that most nearly corresponds to the mounting method of the item.AALX
Mounting Method Style:
Flange type mounting facility
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Tubular, flanged
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
2
MRC:
The length of a straight line which passes through the center of a hole,and terminates at the circumference.AAUB
Hole Diameter:
0.6250 inches
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
3.8750 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
32.4375 inches
MRC:
An indication of the radiation spectrum of the element.ABJA
Element Radiation Specificationtrum:
Noninfrared
MRC:
Indicates the type of heat control included on the item.ABJM
Heat Control Type:
Thermostat
MRC:
The minimum and maximum temperature ratings through which the thermostat will operate.ABJN
Thermostat Range:
-60.0/+250.0 degrees fahrenheit
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the element connection.ABJS
Element Connection Style:
Wire lead w/terminal lug
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.9375 inches
MRC:
The length of a straight line which passes through the center of a flange,and terminates at the circumference.ABKK
Flange Diameter:
4.000 inches
MRC:
A measurement of the longest dimension of a mounting facility,in distinction from width.ABKP
Mounting Facility Length:
6.3125 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
4.5000 inches
MRC:
A measurement taken at right angles to the length of the mounting facility,in distinction from thickness.ABKS
Mounting Facility Width:
0.9375 inches
MRC:
The number of holes or slots included.ABKT
Hole Or Slot Quantity:
8
MRC:
A measurement of the smallest dimension of a flange,in distinction from length or width.ABKU
Flange Thickness:
4.000 inches
MRC:
The number of heats at which the item will operate.ABNR
Heat Quantity:
1
MRC:
The heat output of the heated portion of the surface area of the heating element.ABNS
Watt Density Rating:
23.2 per square inch single voltage
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
25.5000 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Part of immersion heater kas-6t2-1010-m7-4"-150 lb. Steel flange that goes on usns stalwart class tagos
MRC:
The maximum rated power that an item can safely consume or provide,measured in watts.AZQH
Maximum Wattage Rating In Watts:
1500.0 single voltage
MRC:
The number of elements in the item.BHHK
Element Quantity:
1
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
240.0 dc single voltage
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel comp 304 resistance wire