TXT
묘사:
Hydraulic System Comp Test Stand
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Lgm-30 missile
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Electric motor
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Fixed
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor
MRC:
An indication of whether or not a design feature for testing engine driven hydraulic pumps is included.CGYK
Engine Driven Hydraulic Pump Testing Design Feature:
Not included
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Agav
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
480.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
65 l x 74 w x 75in h; 5000lbs; requires nitrogen, water, facility air pressure supplies in addition to electrical for operation
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Supports dynamic build up, adjustment, and acceptance testing of auxiliary power supply pump assembly units under test and aps pressure switch subassemblies. Capable of static testing 5 units at one time
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Serd apstsu0003