TXT
묘사:
Alternating Current Motor
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
7.016 inches
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
50000.0 feet
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Totally enclosed
MRC:
Indicates the specific arrangement in which wire is wound on a form or is formed by winding.AXCP
Winding Type:
Induction-squirrel cage
MRC:
The means of attaching the item.AXGY
Mounting Method:
Pad
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Ambient air
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
Load
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
2.2100 horsepower output
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
-65.0 operating degrees fahrenheit and 160.0 operating degrees fahrenheit
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
10800.0 single full load
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
7.200 single input
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
200.0 line to neutral single input
MRC:
The number of alternating current phases.FAAZ
Phase:
Three input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0 input
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 receptacle