부품 정보
As differntiated by inlet/outlet connection pipe size, inlet/outlet connection type
MRC:
The design of the body of the item.ALCS
Body Design:
Straight pattern
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Steel body err-100 err-100
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Steel, corrosion resisting working parts err-100 err-100
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Steel body
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Steel, corrosion resisting working parts
MRC:
Indicates the design type of the item.APGF
Design Type:
Pulsating
MRC:
The maximum steam pressure at which the item is designed to operate.AXSW
Maximum Steam Working Pressure:
600.0 pounds per square inch
MRC:
An indication of whether or not a strainer is included.BMBL
Strainer:
Included
MRC:
The rated capacity of the item at maximum working pressure.BZSX
Rated Capacity At Maximum Working Pressure:
4000.0 pounds of water per hour
MRC:
An indication of whether or not the inlet and/or outlet connection(s) is identical.BZTB
Inlet/outlet Connection Similarity:
Identical
MRC:
The value used to define the nominal diameter of the inlet and/or outlet connection pipe.BZTC
Inlet/outlet Connection Pipe Size:
0.750 inches
MRC:
Indicates the type of inlet and/or outlet connection provided.BZTD
Inlet/outlet Connection Type:
Socket welding
MRC:
An indication of whether or not the inlet and/or outlet connection is threaded.BZTH
Inlet/outlet Connection Thread Provision:
Unthreaded
MRC:
Indicates the location of the inlet in relation to the installed position of the item.BZTJ
Inlet Location In Relation To Installed Position:
Lower side
MRC:
Indicates the location of the outlet in relation to the installed position of the item.BZTK
Outlet Location In Relation To Installed Position:
Lower side
MRC:
An indication of whether or not a gage glass is included.BZTL
Gage Glass:
Not included
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Zzzy
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Quality control iaw navships 0948-045-7010 material identification and control instruction for level 1 items