부품 정보
Conduit box solenoid connection; nitrile seal
TXT
묘사:
Directional Control Linear Valve
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
2.5
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Double acting and spring centered
MRC:
A rating which expresses the degree of heat or cold as applied to the operation,or limitation of operation,for each type of service with which an item may be used.CRWH
Maximum Operating Tempurature And Media For Which Designed:
100.0 degrees fahrenheit hydraulic fluid, petroleum base
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
12.0 dc
MRC:
The number of fl0w patterns provided.CYGY
Flow Pattern Quantity:
4
MRC:
The number of spool positions provided.CYGZ
Spool Position Quantity:
3
MRC:
The number of spools provided.CYHB
Spool Quantity:
1
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.TMQY
Furnished Items And Quantity:
1 signal light