TXT
				
				
					묘사:
				
				
					Centrifugal Pump Unit				
			 
			
										
					
						MRC:
						The number of prime movers incorporated in the unit.AAXH
					 
					
						Prime Mover Quantity:
					
					
						1					
				 
							
					
						MRC:
						The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
					 
					
						Prime Mover Cooling Medium:
					
					
						Air					
				 
							
					
						MRC:
						The number of stages incorporated in the item.AAYD
					 
					
						Stage Quantity:
					
					
						1					
				 
							
					
						MRC:
						The number of intake connections included on the item.AAYT
					 
					
						Intake Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of intake connection included on the item.AAYU
					 
					
						Intake Connection Type:
					
					
						Round flange					
				 
							
					
						MRC:
						The number of discharge connections included on the item.AAYV
					 
					
						Discharge Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of discharge connection included on the item.AAYW
					 
					
						Discharge Connection Type:
					
					
						Round flange					
				 
							
					
						MRC:
						Indicates the type of current whether alternating,direct,or both.ACDC
					 
					
						Current Type:
					
					
						Ac					
				 
							
					
						MRC:
						The type of service with which the item is designed to be used.ACKL
					 
					
						Media For Which Designed:
					
					
						Water,  salt					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Dripproof					
				 
							
					
						MRC:
						The number of pumps incorporated in the item.AENC
					 
					
						Pump Quantity:
					
					
						1					
				 
							
					
						MRC:
						The means of cooling used to maintain the required operating temperature of the item.AENK
					 
					
						Cooling Method:
					
					
						Air to air cooled					
				 
							
					
						MRC:
						A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.AFJK
					 
					
						Cubic Measure:
					
					
						4.0000 cubic feet					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Used as hot water circulation pump onboard 378 whec hull numbers 715, 716, 718 and 721 coast guard vessels					
				 
							
					
						MRC:
						The maximum rated capacity delivered by the item.AHYV
					 
					
						Maximum Discharge Flow Rate:
					
					
						30.0 gallons per minute					
				 
							
					
						MRC:
						The sum of the total discharge head and the total suction lift.AHYX
					 
					
						Total Head:
					
					
						15.000 feet					
				 
							
					
						MRC:
						The speed of the item required to produce its rated capacity.AHYZ
					 
					
						Operating Speed At Rated Capacity:
					
					
						1790.0 revolutions per minute					
				 
							
					
						MRC:
						The position in which the pumping element/s/ is designed to operate.AHZA
					 
					
						Pumping Element Operating Position:
					
					
						Horizontal					
				 
							
					
						MRC:
						The design of a centrifugal pump as determined by the direction of media flow with respect to the axis of the shaft.AHZE
					 
					
						Centrifugal Pump Design:
					
					
						Mixed flow					
				 
							
					
						MRC:
						The number of impellers incorporated in the centrifugal pump.AHZF
					 
					
						Centrifugal Pump Impeller Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of suction produced by the impeller of the centrifugal pump.AHZG
					 
					
						Centrifugal Pump Impeller Suction Type:
					
					
						Single					
				 
							
					
						MRC:
						Indicates the type of prime mover included with the unit.AKDJ
					 
					
						Prime Mover Type:
					
					
						Electric motor					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The electrical current rating,expressed in amperes.AMPS
					 
					
						Current Rating In Amps:
					
					
						1.5					
				 
							
					
						MRC:
						The rated power of the prime mover.CSYL
					 
					
						Prime Mover Power Rating:
					
					
						1.0 horsepower					
				 
							
					
						MRC:
						The total electrical voltage.ELEC
					 
					
						Voltage In Volts:
					
					
						440.0					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Three					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						60.0