MRC:
						The type of electrical circuit in which the item is designed to be used.AACT
					 
					
						Circuit Current For Which Designed:
					
					
						Ac or dc					
				 
							
					
						MRC:
						An overall measurement between specified points of an item,in distinction from height.ABFY
					 
					
						Overall Depth:
					
					
						1.750 inches 					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						5.875 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						3.375 inches 					
				 
							
					
						MRC:
						The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
					 
					
						Furnished Items And Quantity:
					
					
						Detachable cover 1;  test leads 2					
				 
							
					
						MRC:
						Indicates the type of device used to register the condition(s).AMKD
					 
					
						Indicator Type:
					
					
						Digital display					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Hand held					
				 
							
					
						MRC:
						The source of power which provides the energy required for the operation of the item.AWZJ
					 
					
						Power Source:
					
					
						Internal					
				 
							
					
						MRC:
						Indicates the type of display provided.BFQN
					 
					
						Display Type:
					
					
						Liquid crystal					
				 
							
					
						MRC:
						The number of digits displayed.BFQP
					 
					
						Display Digit Quantity:
					
					
						3-1/2					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+1000.0 volts,  dc single indicator 5th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+2.0 megohms single indicator 10th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+2.0 kilohms single indicator 7th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+2.0 volts,  dc single indicator 2nd range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+20.0 megohms single indicator 11th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+20.0 kilohms single indicator 8th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+20.0 volts,  dc single indicator 3rd range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+200.0 kilohms single indicator 9th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+200.0 milliamperes,  dc single indicator 14th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+200.0 millivolts,  dc single indicator 1st range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+200.0 volts,  ac single indicator 12th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+200.0 ohms single indicator 6th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+200.0 volts,  dc single indicator 4th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+600.0 volts,  ac single indicator 13th range					
				 
							
					
						MRC:
						The means provided for selecting a scale.BLSB
					 
					
						Scale Selection Method:
					
					
						Switch					
				 
							
					
						MRC:
						The deviation from a standard or true value for which the item is rated.CTPT
					 
					
						Accuracy Rating:
					
					
						Porm 0.9 pct of reading plus 1 digit single indicator all ranges					
				 
							
					
						MRC:
						The hue or tint of the display.CTQH
					 
					
						Display Color:
					
					
						Black single indicator all ranges					
				 
							
					
						MRC:
						The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
					 
					
						Circuit Attachment Method And Quantity:
					
					
						2 test prod					
				 
							
					
						MRC:
						The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
					 
					
						Operating Voltage Rating In Volts:
					
					
						9.0 dc 					
				 
							
					
						MRC:
						An indication of the nuclear hardness criticality of the item.NHCF
					 
					
						Nuclear Hardness Critical Feature:
					
					
						Nonhardened					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Hand-held					
				 
							
					
						MRC:
						The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
					 
					
						Fsc Application Data:
					
					
						Electrical, electronic properties measuring and test instruments