부품 정보
Gasket sealed and vented
TXT
묘사:
Magnetic Contactor
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.620 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.620 inches
MRC:
The direct current rating for which the item is rated,expressed in amperes.ACUT
Direct Current Rating In Amps:
50.0
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
28.0 volts
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Magnetic
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four 0.169 in. Min dia, 0.177 in. Maximum diameter mtg holes on 2 in. Sq mtg ctr
MRC:
An indication of the characteristic of the operating voltage.ANCN
Operating Voltage Characteristic:
Full
MRC:
The temperature of the medium surrounding an item at which it can be operated.ANDX
Ambient Temp:
-55.0 degrees celsius and 71.0 degrees celsius
MRC:
An indication of whether or not the item is designed in conformance with the national electrical manufacturers association (nema) standards.ANQC
National Electrical Manufacturers Association Standards Design:
Not designed per nema std
MRC:
Indicates the type of control.AQZF
Control Type:
Remote