TXT
묘사:
Portable Duct Type Heater
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Trailer
MRC:
Indicates the heat medium type for which the unit is designed.ABAM
Heat Medium Type:
Air
MRC:
The number of heat outlets included on the item.ABAW
Heat Outlet Quantity:
1
MRC:
The direction in which the heat is discharged from the item.ABAX
Heat Delivery Direction:
Horizontal
MRC:
Indicates the type of outlet(s) provided for the discharge of heat.ABAY
Heat Discharge Outlet Type:
Stationary
MRC:
Indicates the device/s/ provided for the purpose of directing the flow of heat.ABAZ
Heat Directing Device:
Flexible ducts
MRC:
The mechanism used for air circulation.ABBA
Air Circulation Device:
Squirrel cage blower
MRC:
The different speeds at which the item may be operated.ABBB
Speed Adjustments:
Single speed
MRC:
The maximum rated capacity of air flow moved through the item.ABBD
Maximum Air Flow Rate:
810.0 cubic feet per minute
MRC:
Indicates the type of air the item is designed to circulate.ABBE
Circulated Air Type:
Heated
MRC:
Indicates the type of air filter included on the item.ABBF
Air Filter Type:
Replaceable preformed
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
20.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
A linear measurement from the surface to a specified inner point on an item,in distinction from height.AEJZ
Depth:
49.000 inches
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Gasoline engine
MRC:
Indicates the type of device which controls the operation of the item.ALYC
Operating Control Type:
Thermostatic
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
10.0
MRC:
Indicates the type of heating element provided.BDXJ
Heating Element Type:
Combustion chamber
MRC:
The means used for purposes of igniting.BLJC
Ignition Method:
Electrode
MRC:
The chemical compound or mechanical mixture properties of which the inclosure is fabricated.CQSJ
Inclosure Material:
Steel
MRC:
The amount of fuel the item is rated to consume per hour.CQTY
Fuel Consumption Rate Per Hour:
4.0 gallons
MRC:
The rate of heat delivery of the item.CQXD
Heat Delivery Rate:
400000.0 british thermal unit
MRC:
The amount of fuel that the integral tank will hold.CRJT
Integral Fuel Tank Capacity:
20.0 gallons
MRC:
The means by which the fuel is fed to the item.CSGC
Fuel Feed Method:
Internal pump
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
220.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
Indicates the type of fuel(s) for which the item is designed.FUEL
Fuel Type:
80/87 octane gasoline
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
26.000 inches
MRC:
A numeric value which represents a positive whole value without regard to any unit of measure.NMBR
Quantity:
1