MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Leg
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 62.500 inches and 63.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 27.000 inches and 27.500 inches
MRC:
The number of compartments formed by partitions.AFPV
Compartment Quantity:
2
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Dish, soap, metal 1, drain plugs w/quick opening valve 2 and faucet single w/adjustable @flange 4
MRC:
A measurement between specified points of a compartment,in distinction from height.BGZC
Compartment Depth:
16.000 inches
MRC:
The distance from the floor to the top of the rim.BHRW
Distance From Floor To Top Of Rim:
36.000 inches
MRC:
An indication of whether or not an integral drainboard is included.BJQW
Integral Drainboard:
Not included
MRC:
An indication of whether or not a splash back is provided.BJQY
Splash Back:
Provided
MRC:
An indication of whether or not corners are provided on the splash back.BJQZ
Splash Back Corner:
Not provided
MRC:
An indication of whether or not a ledge back is provided.BJRC
Ledge Back:
Not provided
MRC:
The design characterisitc(s) of the rim.BJRD
Rim Design:
Roll
MRC:
An indication of whether or not a steam water heater is included.BJRF
Steam Water Heater:
Not included
MRC:
The length of a straight line which passes through the center of the drain opening,and terminates at the circumference.BJRH
Drain Opening Diameter:
2.000 inches
MRC:
Indicates the location of the drain opening on the item.BJRJ
Drain Opening Location:
Center of each compartment
MRC:
Indicates the location of the supply opening on the item.BJRK
Supply Opening Location:
Splash back of each compartment
MRC:
The center to center distance between the hot/cold supply openings.BJRL
Center To Center Distance Between Hot/cold Supply Openings:
8.000 inches
MRC:
An indication of whether or not a spout opening is provided.BJRM
Spout Opening:
Not provided
MRC:
An indication of whether or not a separate drinking water supply opening is provided.BJRN
Separate Drinking Water Supply Opening:
Not provided
MRC:
An indication of whether or not a spray opening is provided.BJRP
Spray Opening:
Not provided
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
15.000 inches
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Steel, stainless
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel