부품 번호 CR32U35555-55KC

Quartz Crystal Unit

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards
부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
cr32u35555-55kc
비무장화:
Yes - DEMIL/MLI
수명:
측정 단위:
NIIN:
002675112
NSN
국가 주식 번호:
5955-00-267-5112 5955002675112
TXT
묘사:
Quartz Crystal Unit
INC
INC
아이템 이름 코드:
00196
INC
COM
컴플라이언스:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.003 inches
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.238 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.757 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.765 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.750 inches
MRC:
A measurement of the smallest dimension of a body,in distinction from length or width.ADPR
Body Thickness:
0.317 inches
MRC:
An overall measurement of the smallest dimension of an item,in distinction from length or width.ADUM
Overall Thickness:
0.343 inches
MRC:
The length of a straight line which passes through the center of a terminal,and terminates at the circumference.AEBT
Terminal Diameter:
0.050 inches
MRC:
The mode of frequency at which the device is designed to operate.AEHC
Mode Of Oscillation:
Third overtone
MRC:
The frequency at which the item is designed to operate under specified conditions.AEHG
Specified Frequency:
35.5555 kilohertz
MRC:
The permissible frequency deviation when operating at the reference temperature,expressed in percent.AEHK
Frequency Tolerance At Reference Tempurature In Percent:
-0.0005/+0.0005
MRC:
The temperature at the midpoint of the controlled operating temperature range.AEHM
Controlled Reference Temp:
75.0 degrees celsius
MRC:
The temperature range over which units,designed for controlled temperature conditions,will oscillate.AEHN
Operable Tempurature Range:
+70.0/+80.0 degrees celsius
MRC:
None.CQBK
Center To Center Distance Between Terminals:
0.486 inches
MRC:
The permissible frequency deviation within the operating temperature range,expressed in percent.CRFX
Frequency Tolerance For Operating Tempurature In Percent:
-0.002/+0.002
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Oval body, pin terminals

{lang[cimilar]} Quartz Crystal Units

« Oscillators and Piezoelectric Crystals {lang[catalog]}
지금 비교»
맑다 | 숨기다