MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Watertight
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
Actuator Style:
Roller plunger
Actuator Free Position Height:
2.531 inches
Actuator Roller Diameter:
0.500 inches
Actuator Roller Width:
0.156 inches
Housing Height:
2.094 inches
MRC:
A measurement of the longest dimension of the housing,in distinction from width.AFWD
Housing Length:
6.188 inches
MRC:
A measurement taken at right angles to the length of a housing,in distinction from thickness.AFWE
Housing Width:
2.469 inches
Center To Center Distance Between Housing Mounting Facilities Parallel To Length:
4.125 inches
Center To Center Distance Between Housing Mounting Facilities Parallel To Width:
1.078 inches
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
575.0 ac
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, double throw, one position momentary single switch unit
MRC:
The amount to which the actuating force must be reduced to permit the switch to become unactuated.CRRM
Switch Release Force:
8.0 inch-ounces
MRC:
The amount of force required to actuate the switch.CSJN
Switch Actuating Force:
16.0 inch-ounces
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
1.200 amperes resistive ac