TXT
묘사:
Directional Coupler
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.750 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.800 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.890 inches
MRC:
The number of complete cycle changes of radiated electromagnetic energy,per unit of time,for which an item is rated.ANKZ
Radio Frequency Rating:
Between 50.0 megahertz and 400.0 megahertz
MRC:
Indicates the design type of the item.APGF
Design Type:
Bidirectional or unidirectional
MRC:
Indicates the type of unit.APQB
Unit Type:
Coaxial line and transmission line
MRC:
The maximum to minimum voltage standing wave ratio at a specified frequency/ies/.BGPS
Voltage Standing Wave Ratio At Reference Frequency:
1.3 to 1 at 50 to 400 mhz
MRC:
The amount of decrease in power,expressed in decibels.BGPX
Power Loss In Decibels:
0.5 and 0.6
MRC:
The nomenclature by which the terminal fitting is identified.BGPY
Terminal Fitting Name:
Bnc female connectors
MRC:
An indication of the designed use of the terminal fitting.BGQC
Terminal Fitting Usage Design:
Main line and secondary line